A.PARAMETERS APPENDIX B-63944EN-1/02
- 400 -
3294 Start number of tool offset values whose input by MDI is disabled
3295
Number of tool offset values (from the start number) whose input by MDI is
disabled
[Input type] Parameter input
[Data type] Word path
[Valid data range] 0 to 999
When the modification of tool offset values by MDI key input
is to be disabled using bit 0 (WOF) of parameter No.3290 and bit 1
(GOF) of parameter No.3290, parameter Nos. 3294 and 3295 are used
to set the range where such modification is disabled. In parameter
No.3294, set the offset number of the start of tool offset values whose
modification is disabled. In parameter No.3295, set the number of
such values.
In the following cases, however, none of the tool offset values may be
modified:
- When 0 or a negative value is set in parameter No. 3294
- When 0 or a negative value is set in parameter No. 3295
- When a value greater than the maximum tool offset number is set
in parameter No. 3294
In the following case, a modification to the values ranging from the
value set in parameter No. 3294 to the maximum tool offset number is
disabled:
When the value of parameter No. 3294 added to the value of
parameter No. 3295 exceeds the maximum tool offset number
When the offset value of a prohibited number is input through the
MDI panel, the warning "WRITE PROTECT" is issued.
[Example]
When the following parameter settings are made, modifications to
both of the tool geometry offset values and tool wear offset values
corresponding to offset numbers 51 to 60 are disabled:
- Bit 1 (GOF) of parameter No. 3290 = 1 (to disable tool geometry
offset value modification)
- Bit 0 (WOF) of parameter No. 3290 = 1 (to disable tool wear
offset value modification)
- Parameter No. 3294 = 51
- Parameter No. 3295 = 10
If the setting of bit 0 (WOF) of parameter No. 3290 is set to 0 without
modifying the other parameter settings above, tool geometry offset
value modification only is disabled, and tool wear offset value
modification is enabled.