A.PARAMETERS APPENDIX B-63944EN-1/02
- 412 -
NOTE
1 This parameter is valid when bit 6 (EVO) of
parameter No. 5001 is set to 0.
2 The operation of this parameter set to 1 is valid
even if a new compensation value is further
changed by MDI input or a G10 command before
the new compensation value becomes effective.
3 The operation of this parameter set to 1 is invalid if
a reset operation is performed before a new
compensation value becomes effective.
#7 #6 #5 #4 #3 #2 #1 #0
5042 OFE OFD OFC OFA
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 0 OFA
# 1 OFC
# 2 OFD
# 3 OFE These bits are used to specify the increment system and valid data
range of a tool offset value.
For metric input
OFE OFD OFC OFA Unit Valid data range
0 0 0 1 0.01mm ±9999.99mm
0 0 0 0 0.001mm ±9999.999mm
0 0 1 0 0.0001mm ±9999.9999mm
0 1 0 0 0.00001mm ±9999.99999mm
1 0 0 0 0.000001mm ±999.999999mm
For inch input
OFE OFD OFC OFA Unit Valid data range
0 0 0 1 0.001inch ±999.999inch
0 0 0 0 0.0001inch ±999.9999inch
0 0 1 0 0.00001inch ±999.99999inch
0 1 0 0 0.000001inch ±999.999999inch
1 0 0 0 0.0000001inch ±99.9999999inch