A.PARAMETERS APPENDIX B-63944EN-1/02
- 424 -
#7 #6 #5 #4 #3 #2 #1 #0
5201 OV3 OVU
[Input type] Parameter input
[Data type] Bit path
# 3 OVU The increment unit of the override parameter (No.5211) for tool rigid
tapping extraction is:
0: 1%
1: 10%
# 4 OV3 A spindle speed for extraction is programmed, so override for
extraction operation is:
0: Disabled.
1: Enabled.
#7 #6 #5 #4 #3 #2 #1 #0
5203 OVS
[Input type] Parameter input
[Data type] Bit path
# 4 OVS In rigid tapping, override by the feedrate override select signal and
cancellation of override by the override cancel signal is:
0: Disabled.
1: Enabled.
When feedrate override is enabled, extraction override is disabled.
The spindle override is clamped to 100% during rigid tapping,
regardless of the setting of this parameter.
5211 Override value during rigid tapping extraction
[Input type] Parameter input
[Data type] Word path
[Unit of data] 1% or 10%
[Valid data range] 0 to 200
The parameter sets the override value during rigid tapping extraction.
NOTE
The override value is valid when DOV in parameter
No.5200 #4 is "1". When OVU (bit 3 of parameter
No.5201) is 1, the unit of set data is 10%. An
override of up to 200% can be applied to extraction.