OPERATION
B–63124EN/01
2. OPERATIONAL DEVICES
379
If a hardware failure or installation error occurs, the system displays one
of the following three types of screens then stops.
Information such as the type of printed circuit board installed in each slot
is indicated. This information and the LED states are useful for failure
recovery.
SLOT CONFIGURATION DISPLAY
0 : 003E4000
1 : 30464202
2 : 00504303
3 :
4 :
5 :
0 :
1 :
2 :
3 :
4 :
5 :
Physical slot number (sec-
ondary)
Information such as the module ID of an installed printed circuit board
Physical slot number (pri-
mary)
Internally–assigned slot number
Module function
Types of printed circuit boards
For more information about the types of printed circuit boards and module
functions, refer to the maintenance manual (B–63005EN).
2.5.2
Screen Displayed at
Power–on
Slot status display