4. DESCRIPTION OF PARAMETERS
B–63010EN/02
116
S When a three–axis amplifier is used, the requirement for a two–axes
amplifier described above applies to the first and second axes, and the
requirement for a one–axis amplifier, again described above, applies to
the third axis.
S When an odd number is specified for parameter No.1023, the fast type
interface must be used. However, the slow type may be used for an EGB
workpiece axis, learning control axis, high–speed current loop axis, and
high–speed interface axis.
S When an even number is specified for parameter No.1023, only the
slow type interface can be used. (The FSL bit must always be set to 1.)
Controlled
axis
number
1
2
3
4
5
6
Program
axis name
No.1020
X
Y
Z
A
B
C
Servo axis
number
No.1023
1
2
3
4
5
6
Interface
type
Fast/Slow
F
F
S
S
F
S
CNC
2–axis
amplifier
2–axis
amplifier
1–axis
amplifier
X (Fast)
A (Slow)
Y (Fast)
Z (Slow)
B (Fast)
C (Slow)
1–axis
amplifier
IO1 A first I/O module supporting FSSB is:
0 : Not used.
1 Used.
IO2 A second I/O module supporting FSSB is:
0 : Not used.
1 Used.
PM1 The first pulse module is:
0 : Not used.
1 : Used.
PM2 The second pulse module is:
0 : Not used.
1 : Used.
NOTE
When automatic setting mode is selected for FSSB setting
(when the FMD parameter (bit 0 of parameter No.1902) is set
to 0), parameter No.1905 is automatically set when input is
performed with the FSSB setting screen. When manual
setting 2 mode is selected for FSSB setting (when the FMD
parameter (bit 0 of parameter No.1902) is set to 1),
parameter No.1905 must be set directly. When a pulse
module is used, a connector number must be set in the
corresponding parameter (No.1936 or No.1937).