B–63010EN/02
4. DESCRIPTION OF PARAMETERS
413
#7
8100
#6
DSB
#5
COF
#4 #3 #2 #1
IAL
#0
RST
RST
[Data type] Bit
RST Reset key on the MDI panel
0 : Effective for both paths, or in the M series, for both machining and
background drawing sides
1 : Effective for a path selected by the path selection signal, or in the M
series, for the background drawing side.
IAL When an alarm is raised in one tool post in the automatic operation mode,
0 : The other path enters the feed hold state and stops.
1 : The other path continues operation without stopping.
COF Tool post 1 and tool post 2 (under two–path control) use:
0 : Their own tool compensation memories.
1 : Common tool compensation memory.
DSB The special single block function (under two–path control) is:
0 : Disabled.
1 : Enabled.
8110 Waiting M code range (minimum value)
[Data type] 2–word
[Valid data range] 0 and 100 to 99999999
This parameter specifies the minimum value of the waiting M code.
The waiting M code range is specified using parameter 8110 (minimum
value) and parameter 8111 (maximum value).
(parameter 8110) ≤ (waiting M code) ≤ (parameter 8111)
NOTE
A value of 0 indicates that the waiting M code is not used.
8111 Waiting M code range (maximum value)
[Data type] 2–word
[Valid data range] 0 and 100 to 99999999
This parameter specifies the maximum value of the waiting M code.
4.64
PARAMETERS OF
TWO–PATH
CONTROL