4. DESCRIPTION OF PARAMETERS
B–63010EN/02
292
5411
Magnification used when scaling magnification is not specified
Setting entry is acceptable.
[Data type] 2–word
[Unit of data] 0.001 or 0.00001 times (Selected using SCR, #7 of parameter No.5400)
[Valid data range] 1 to 999999
This parameter sets the scaling magnification. This setting value is used
when a scaling magnification (P) is not specified in the program.
NOTE
Parameter No.5421 becomes valid when scaling for every
axis is valid. (XSC, #6 of parameter No.5400 is “1”.)
5412
Rapid traverse rate for a hole machining cycle in three–dimensional coordinate
conversion mode
[Data type] 2–word
[Units of data], [Valid data range]
Valid data range
Increment system Units of data
IS–A, IS–B IS–C
Millimeter machine 1 mm/min 30 to 240000 6 to 100000
Inch machine 0.1 inch/min 30 to 96000 6 to 48000
Rotation axis 1 deg/min 30 to 240000 6 to 100000
5421
Scaling magnification for every axis
Setting entry is acceptable.
[Data type] 2–word axis
[Unit of data] 0.001 or 0.00001 times (Selected using SCR, #7 of parameter No.5400)
[Valid data range] –999999 to –1, 1 to 999999
This parameter sets the scaling magnification for every axis.