4. DESCRIPTION OF PARAMETERS
B–63010EN/02
210
[Valid data range] 0, 1 to 32767
If bit 3 (MPP) of parameter No. 3703 is set to 1, set the P code to select
each spindle under multi–spindle control. Specify the P code in a block
containing the S command.
Example) If the P code value for selecting the second spindle is set to 3,
S1000 P3;
causes the second spindle to rotate at S1000.
NOTE
1 This parameter is valid if bit 3 (MPP) of parameter No. 3703
is set to 1.
2 If this parameter is set to 0, the corresponding spindle
cannot be selected by a P code.
3 Under multipath control, the P code specified here is valid for
each path.
For instance, if the P code to select the first spindle of path
2 is set to 21, specifying S1000 P21; in path 1 causes the first
spindle of path 2 to be rotated at S1000.
4 Identical P code values cannot be used for different
spindles. (Identical P code values cannot be used even if the
paths are different.)
5 If this parameter is used (bit 3 (MPP) of parameter No. 3703
is set to 1), signals SWS1 to SWS4 <G027 bits 0 to 2, G026
bit 3> and SLSPA/SLSPB <G063 bits 2 and 3> become
invalid.
6 To use this parameter, the multi–spindle control function is
needed.
7 Parameter No. 3784 is valid only for Series 16i.
3802 Maximum speed of the second spindle
[Data type] Word
[Unit of data] min
–1
[Valid data range] 0 to 32767
Parameter sets the maximum speed for the second spindle.
When a command specifying a speed exceeding the maximum speed of
the spindle is specified, or the speed of the spindle exceeds the maximum
speed because of the spindle speed override function, the spindle speed is
clamped at the maximum speed set in the parameter.