B–63010EN/02
4. DESCRIPTION OF PARAMETERS
415
IFE A tool post interference check (T series) and inter–2–path interference
check (M series) are:
0 : Performed.
1 : Not performed.
ZCL Specifies whether interference along the Z axis is checked while checking
interference between tool posts.
0 : Checked
1 : Not checked (Only interference along the X axis is checked.)
8141
Distance along the X–axis from a path–1 reference point to a path–2 reference point
8142
Distance along the Y–axis from a path–1 reference point to a path–2 reference point
8143
Distance along the Z–axis from a path–1 reference point to a path–2 reference point
[Data type] 2–word
[Unit of data]
Increment system IS–A IS–B IS–C Units
Millimeter machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
Rotation axis 0.01 0.001 0.0001 deg
[Valid data range] –99999999 to 99999999
8144
Interference check area figure data AI (BI)
8145
Interference check area figure data AJ (BJ)
8146
Interference check area figure data AK (BK)
8147
Interference check area figure data AX (BX)
8148
Interference check area figure data AY (BY)
8149
Interference check area figure data AZ (BZ)
[Data type] 2–word
[Unit of data]
Increment system IS–A IS–B IS–C Units
Millimeter machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
Rotation axis 0.01 0.001 0.0001 deg
[Valid data range] –99999999 to 99999999