4. DESCRIPTION OF PARAMETERS
B–63010EN/02
438
8311 Axis number of master axis in synchronous control
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Byte axis
<For the T Series>
Select a master axis and slave axis in simple synchronous control. Set a
master axis number with a slave axis. For the parameters for the first axis
through the fourth axis of parameter No.8311, set the following:
Units digit of the parameter for the first axis –>
Set the axis number of a master axis for the first axis.
Tens digit of the parameter for the first axis –>
Set the axis number of a master axis for the second axis.
Units digit of the parameter for the second axis –>
Set the axis number of a master axis for the third axis.
Tens digit of the parameter for the second axis –>
Set the axis number of a master axis for the fourth axis.
Units digit of the parameter for the third axis –>
Set the axis number of a master axis for the fifth axis.
Tens digit of the parameter for the third axis –>
Set the axis number of a master axis for the sixth axis.
Units digit of the parameter for the fourth axis –>
Set the axis number of a master axis for the seventh axis.
Tens digit of the parameter for the fourth axis –>
Set the axis number of a master axis for the eighth axis.
Number Tens digit Units digit
First axis Second axis First axis
Second axis Fourth axis Third axis
Third axis Sixth axis Fifth axis
Fourth axis Eighth axis Seventh axis
Note that the axis number settings are as follows:
0 –> First axis, 1 –> Second axis, 2 –> Third axis, 3 –> Fourth axis
Example: If the master and slave axes are assigned as the third and fourth
axes, respectively, set up as follows:
No. 8311 First: 00
Second: 20
Third: 00
Fourth: 00
NOTE
For an axis for which 0 is set, the first axis serves as the
master axis. So, when the control signal for the axis is set
to 1, the first axis serves as a master axis, and synchronous
control is exercised.