4. DESCRIPTION OF PARAMETERS
B–63010EN/02
452
#7
8451
#6 #5 #4
ZAG
#3 #2 #1 #0
USENOF
Setting point
[Data type] Bit
USE Automatic velocity control is:
0 : Not applied.
1 : Applied.
ZAG The velocity is:
0 : Not determined according to the angle at which the machine descends
along the Z–axis.
1 : Determined according to the angle at which the machine descends
along the Z–axis.
NOF In a block where automatic velocity control is validated, the F command
is:
0 : Validated.
1 : Ignored.
8452
Range of velocity fluctuation to be ignored
Setting input
[Data type] Byte
[Unit of data] %
[Valid range] 0 to 100 (Standard setting: 10
)
8456
Area–2 override
[Data type] Word
[Unit of data] %
[Valid range] 0 to 100 (Standard setting: 80
)
This parameter specifies an override in area 2 of velocity calculation
considering the cutting load.
8457
Area–3 override
[Data type] Word
[Unit of data] %
[Valid range] 0 to 100 (Standard setting: 70
)
This parameter specifies an override in area 3 of velocity calculation
considering the cutting load.