4. DESCRIPTION OF PARAMETERS
B–63010EN/02
284
5321
Spindle backlash in rigid tapping (first–stage gear)
Spindle backlash in rigid tapping
5322
Spindle backlash in rigid tapping (second–stage gear)
5323
Spindle backlash in rigid tapping (third–stage gear)
5324
Spindle backlash in rigid tapping (fourth–stage gear)
5325
Spindle backlash in rigid tapping using the second spindle (first–stage gear)
Spindle backlash in rigid tapping using the second spindle
5326
Spindle backlash in rigid tapping using the second spindle (second–stage gear)
5327
Spindle backlash in rigid tapping using the third spindle (first–stage gear)
Spindle backlash in rigid tapping using the third spindle
5328
Spindle backlash in rigid tapping using the third spindle (second–stage gear)
[Data type] Byte
[Unit of data] Detection unit
[Valid data range] 0 to 127
Each of these parameters is used to set a spindle backlash.
NOTE
When rigid tapping is performed using the second and third
spindles
• When the SPR parameter (bit 1 of parameter No.5204)
is set to 1, the settings of parameters No.5325 and
No.5326 are applied to the second spindle, while the
settings of parameters No.5227 and No.5228 are applied
to the third spindle.
• When the SPR parameter (bit 1 of parameter No.5204)
is set to 0, the settings of parameters No.5321 and
No.5322 are applied to the second spindle and third
spindle, as well as to the first spindle.