B–63010EN/02
4. DESCRIPTION OF PARAMETERS
365
7015 Least command increment setting for jog feed
[Data type] Word
[Unit of data]
Increment system IS–A IS–B IS–C Unit
Metric machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
Rotation axis 0.01 0.001 0.0001 deg
[Valid data range] 0 to 10000
This parameter sets the least command increment for jog feed when PMC
signal JGUNIT <bit 0 of G0023> is set to 1. If the setting of this parameter
is 0, a value of 1 is recognized.
#7
7050
#6
MI1
#5
MI0
#4 #3 #2 #1 #0
RV1
NOTE
After setting this parameter, turn off the power. Then, turn
the power back on to enable the setting.
[Data type] Bit
RV1 When the tool moves backwards after feed hold during forward feed with
the retrace function:
0 : The block is split at the feed hold position and stored.
1 : The block is stored without being split.
Command block in program
– – – – – – – *– – – – – – –>
If the tool moves backwards after feed hold at position indicated
with *
When RV1 = 0
The block is split into two blocks and stored.
– – – – – – – > – – – – – – – >
When RV1 = 1
The block is stored as is.
– – – – – – – – – – – – – – – >
MI0, MI1 Set a batch pass quantity in AI control mode.
MI1 MI0 Batch pass quantity
0 0 1
0 1 2