4. DESCRIPTION OF PARAMETERS
B–63010EN/02
418
NOTE
When the master and slave axes have different
acceleration/deceleration time constants, set 1.
NRS When the system is reset, synchronous, composite, or superimposed
control is:
0 : Released.
1 : Not released.
#7
8161
#6 #5
CRZ
#4
CMW
#3 #2 #1
CZM
#0
NMR
[Data type] Bit
NMR When an axis subject to mixed control is placed in servo–off state:
0 : Mixed control is stopped.
1 : Mixed control is not stopped, provided bit 0 (FUP) of parameter
No.1819 is set to 1 to disable follow–up for the axis.
NOTE
Mixed control is not stopped only when bit 0 (FUP) of
parameter No.1819 is set to 1. If follow–up is disabled with
the follow–up signal (*FLWU <G007 bit 5> =1), mixed control
is stopped.
CZM When two Cs contour axes are subject to mixed control, the function for
mixing zero point return commands for Cs contour axes is:
0 : Not used
1 : Used
CMW When the function for mixing zero point return commands for Cs contour
axes is used (CZM = 1) with the workpiece coordinate system set
function, at completion of Cs zero point return, the coordinate system is
set:
0 : Based on the machine coordinate of the Cs contour axis on the same
path.
1 : Based on the machine coordinate of the Cs contour axis of the
composite destination.
CRZ When the function for mixing zero point return commands for Cs contour
axes is used (CZM = 1), for a positioning command for a CS contour axis
immediately after composite control switching between Cs contour axes:
0 : Normal positioning operation is performed.
1 : Positioning operation including zero point return is performed.