B–63010EN/02
4. DESCRIPTION OF PARAMETERS
467
#7
8701
#6
CTV
#5 #4 #3 #2
WPR
WPR
#1
PLD
PLD
#0
[Data type] Bit
PLD When the P–code loader function is used (macro compiler/executor):
0 : AM is initialized and the entire contents of RAM are rewritten.
1 : RAM is not initialized, being overwritten instead
WPR The function that allows parameters that are rewritten using the PMC
window to be enabled during automatic operation is:
0 : Disabled.
1 : Enabled.
CTV When CAP II is provided, 1 must be specified.
#7
LFM8702
#6 #5 #4 #3 #2 #1 #0
[Data type] Bit
LFM At the beginning of program uploading in response to a request using the
data window library:
0 : “LF+%” is not output.
1 : “LF+%” is output.
#7
8703
#6 #5 #4 #3 #2 #1
LCL
#0
DLF
[Data type] Bit
DLF If an incomplete program file is created because program registration,
performed via a communication board such as MAP is interrupted by a
reset or alarm, the file is:
0 : Not deleted.
1 : Deleted.
NOTE
This parameter is used with the OSI/Ethernet function.
LCL When a change in the internal state of the CNC (such as a change in the
number of part programs or selected programs) occurs, information about
the change is:
0 : Not sent to the host.
1 : Sent to the host.
NOTE
This parameter is used with the OSI/Ethernet function.