4. DESCRIPTION OF PARAMETERS
B–63010EN/02
120
1931 Connector number for the first pulse module (dedicated to the FSSB setting screen)
1932 Connector number for the second pulse module (dedicated to the FSSB setting screen)
NOTE
After these parameters have been set, the power must be
turned off then back on for the settings to become effective.
[Data type] Byte axis
[Valid data range] 0 to number of connectors provided on each pulse module
When a pulse module is used, these parameters set a pulse module
connector number for each axis.
NOTE
These parameters are set using the FSSB setting screen.
So, these parameters should not normally have to be
specified directly. These parameters need not be set in
FSSB manual setting 2 mode.
1933 Cs contour control axis (dedicated to the FSSB setting screen)
NOTE
After this parameter has been set, the power must be turned
off then back on for the setting to become effective.
[Data type] Byte axis
[Valid data range] 0, 1
When Cs contour control is to be applied for an axis, this parameter must
be set to 1 for that axis.
NOTE
This parameter is set using the FSSB setting screen. So,
this parameter should not normally have to be specified
directly. This parameter need not be set in FSSB manual
setting 2 mode.
1934
Master and slave axis numbers subject to tandem control
(dedicated to the FSSB setting screen)
NOTE
After this parameter has been set, the power must be turned
off then back on for the setting to become effective.
[Data type] Byte axis
[Valid data range] 0 to 8
This parameter is used to set an odd number, and the subsequent even
number, for a master axis and slave axis subject to tandem control,
respectively.