4. DESCRIPTION OF PARAMETERS
B–63010EN/02
374
7160 Approach handle clamp feedrate
[Data type] 2–word
[Unit of data, Valid data range]
Valid data range
Increment system Unit of data
IS–A, IS–B IS–C
Metric machine 1 mm/min 0 to 15000 0 to 12000
Inch machine 0.1 inch/min 0 to 6000 0 to 4800
Rotation axis 1 deg/min 0 to 15000 0 to 12000
When the setting is 0, the feedrate is not clamped.
7161 Guidance handle clamp feedrate
[Data type] 2–word
[Unit of data, Valid data range]
Valid data range
Increment system Unit of data
IS–A, IS–B IS–C
Metric machine 1 mm/min 0 to 15000 0 to 12000
Inch machine 0.1 inch/min 0 to 6000 0 to 4800
Rotation axis 1 deg/min 0 to 15000 0 to 12000
When the setting is 0, the feedrate is not clamped.
4.53
PARAMETERS OF
MANUAL LINE AND
ARC FUNCTIONS