4. DESCRIPTION OF PARAMETERS
B–63010EN/02
388
#7
7570
#6 #5 #4 #3 #2 #1
FK1
#0
FTP
[Data type] Bit
FTP Fixture offset type setting
0 : Movement type
(The tool moves when the fixture offset changes.)
1 : Shift type
(The tool does not move when the fixture offset changes.)
FK1 When bit 7 (KEY) of parameter No. 3290 is set to 0, input of fixture offset
data using MDI keys is:
0 : Disabled when signal KEY1 is set to 0 or enabled when the signal is
set to 1.
(Same as for the input enable conditions for the tool offset value)
1 : Enabled when signal KEY1 is set to 0 or disabled when the signal is
set to 1.
(Inverse of the input enable conditions for the tool offset value)
#7
7575
#6 #5 #4 #3 #2 #1 #0
FAX
[Data type] Bit axis
FAX Axis–by–axis fixture offset is:
0 : Disabled.
1 : Enabled.
7580
Specification of a rotation axis for fixture offset (first group)
7581
Specification of linear axis 1 used for selecting a plane for fixture offset (first group)
7582
Specification of linear axis 2 used for selecting a plane for fixture offset (first group)
7583
Specification of a rotation axis for fixture offset (second group)
7584
Specification of linear axis 1 used for selecting a plane for fixture offset (second group)
7585
Specification of linear axis 2 used for selecting a plane for fixture offset (second group)
7586
Specification of a rotation axis for fixture offset (third group)
4.58
PARAMETERS OF
ROTARY TABLE
DYNAMIC FIXTURE
OFFSET