4. DESCRIPTION OF PARAMETERS
B–63010EN/02
404
7950
α axis machine zero–degree point offset
7951
β axis machine zero–degree point offset
[Data type] 2–word
[Unit of data] 0.001 deg
[Valid data range] 0 to 360000 (Standard setting = 0)
These parameters set machine zero–degree point offset values for the α
axis and β axis.
NOTE
Never set a value other than 0, 90000, 180000, or 270000.
7952
Upper limit on α axis machining speed
7953
Upper limit on β axis machining speed
[Data type] 2–word
[Unit of data] deg/min
[Valid data range] 6 to 15000
These parameters set the upper limits on the α axis and β axis machining
speeds.
If the α axis or β axis speeds are greater than the values set in these
parameters when attitude control is exercised in sync with move
commands for the X–axis, Y–axis, and Z–axis, movement along the
X–axis, Y–axis, and Z–axis is performed at feedrates determined from the
α axis or β axis speeds, clamped to the specified upper limits.
When using interaction control, set the same value for the α axis or β axis.
7954
Length of the first arm
7955
Length of the second arm
[Data type] 2–word
[Unit of data] deg/min
[Valid data range] 0 to 500000
These parameters set the lengths of the first and second arms.
When using attitude control A (zero offset type nozzle), set 0 for these
parameters.