4. DESCRIPTION OF PARAMETERS
B–63010EN/02
138
#7
OHS
3106
#6
DAK
#5
SOV
SOV
#4
OPH
OPH
#3
SPD
#2 #1
GPL
GPL
#0
OHS
[Data type] Bit
DHD Simultaneous editing of the program screens of the two paths is:
0 : Not performed.
1 : Performed.
GPL On the program list screen, the list–by–group function is:
0 : Disabled
1 : Enabled
SPD Names for actual spindle speed values are displayed:
0 : Regardless of the selected spindle position coder
(in second position coder selection signal (PC2SLC))
1 : Depending of the selected spindle position coder
(in second position coder selection signal (PC2SLC))
SPD=0 SPD=1
Spindles 1 and 2 Spindles 1 Spindles 2
S S1 S2
SACT
ACT, S
SACT1 SACT2
NOTE
When SPD is set to 1, during Two–path control, the actual
spindle speed names for a spindle of path 2 are displayed
in reverse video.
OPH The operation history screen is:
0 : Not displayed.
1 : Displayed.
SOV The spindle override value is:
0 : Not displayed.
1 : Displayed.
NOTE
This parameter is enabled only when bit 2 (DPS) of
parameter No.3105 is set to 1.
DAK When absolute coordinates are displayed in the three–dimensional
coordinate conversion mode:
0 : Coordinates in the program coordinate system are displayed.
1 : Coordinates in the workpiece coordinate system are displayed.
OHS Operation history sampling is:
0 : Performed.
1 : Not performed.