4. DESCRIPTION OF PARAMETERS
B–63010EN/02
324
6161 First–stage rapid traverse rate
6162 Second–stage rapid traverse rate
6163 Third–stage rapid traverse rate
6164 Fourth–stage rapid traverse rate
6165 Fifth–stage rapid traverse rate
6166 Sixth–stage rapid traverse rate
6167 Seventh–stage rapid traverse rate
[Data type] 2–word axis
[Unit of data], [Valid data range]
Valid data range
Increment system Units of data
IS–A, IS–B IS–C
Millimeter machine 1 mm/min 30 to 240000 30 to 100000
Inch machine 0.1 inch/min 30 to 96000 30 to 48000
Rotation axis 1 deg/min 30 to 240000 30 to 100000
Specify rapid traverse rates for each axis.
6171 First–stage rapid traverse time constant
6172 Second–stage rapid traverse time constant
6173 Third–stage rapid traverse time constant
6174 Fourth–stage rapid traverse time constant
6175 Fifth–stage rapid traverse time constant
6176 Sixth–stage rapid traverse time constant
6177 Seventh–stage rapid traverse time constant
[Data type] Word axis
[Unit of data] ms
[Valid data range] 8 to 4000
Specify rapid traverse time constants for each axis.
6181 First–stage rapid traverse servo loop gain
6182 Second–stage rapid traverse servo loop gain
6183 Third–stage rapid traverse servo loop gain
6184 Fourth–stage rapid traverse servo loop gain
6185 Fifth–stage rapid traverse servo loop gain
6186 Sixth–stage rapid traverse servo loop gain
6187 Seventh–stage rapid traverse servo loop gain
[Data type] Word axis
[Unit of data] 0.01 s
-1
[Valid data range] 1 to 9999
Specify rapid traverse servo loop gains for each axis.