4. DESCRIPTION OF PARAMETERS
B–63010EN/02
288
5355
Positional deviation limit imposed during spindle movement in rigid tapping using
the third spindle
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter is used to set a positional deviation limit imposed during
spindle movement in rigid tapping using the third spindle.
NOTE
This parameter is enabled when the SPR parameter (bit 1 of
parameter No.5204) is set to 1.
5356
Positional deviation limit imposed while the tapping axis is stopped in rigid tap-
ping using the third spindle
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter is used to set a positional deviation limit imposed while
the tapping axis is stopped in rigid tapping using the third spindle.
NOTE
This parameter is enabled when the SPR parameter (bit 1 of
parameter No.5204) is set to 1.
5357
Positional deviation limit imposed while the spindle is stopped in rigid tapping
using the third spindle
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter is used to set a positional deviation limit imposed while
the spindle is stopped in rigid tapping using the third spindle.
NOTE
This parameter is enabled when the SPR parameter (bit 1 of
parameter No.5204) is set to 1.