B–63010EN/02
4. DESCRIPTION OF PARAMETERS
191
SS3 In serial spindle control, the third spindle is:
0 : Not used.
1 : Used.
NOTE
This parameter is valid, single–path control and the spindle
output option and the three–spindle serial output option are
provided.
Parameter setting
SS4
(No.3704#1)
SS3
(No.3701#5)
SS2
(No.3701#4)
Serial spindles to be used
0 0 0 First spindle only
0 0 1 First and second spindles
0 1 0 First and third spindles
0 1 1 First to third spindles
1 1 0 First, third, and fourth spindles
1 1 1 First to fourth spindles
NOTE
1 To connect a serial spindle as the third or fourth spindle, the
function of three/four–spindle serial output is required.
2 The fourth serial spindle can be used just in Series 16i.
#7
ECS
3702
ECS
#6
ESS
ESS
#5
EAS
EAS
#4
ESI
#3
OR2
OR2
#2
OR1
OR1
#1
EMS
EMS
#0
OR3
OR3
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
OR3 The spindle orientation function based on an externally set stop position
is:
0 : Not used by the third spindle motor.
1 : Used by the third spindle motor.
NOTE
When the spindle orientation function based on an externally
set stop position is used, the position coder–based spindle
orientation stop position set parameters (No.4031 and
No.4204) are ineffective.
EMS Multi–spindle control function
0 : Used
1 : Not used