B–63010EN/02
4. DESCRIPTION OF PARAMETERS
159
3216 Increment in sequence numbers inserted automatically
Setting entry is acceptable.
[Data type] Word
[Valid data range] 0 to 9999
Set the increment for sequence numbers for automatic sequence number
insertion (when SEQ, #5 of parameter 0000, is set to 1.)
3218
Program number to be registered in synchronous input/output operation (4–digit
program number)
[Data type] Word
[Valid data range] 1 to 9999
When a program entered through the input/output unit is executed and
registered in memory at the same time in synchronous input/output
operation, this parameter sets a program number for that program.
NOTE
1 If a value that falls outside the valid data range is specified,
the number of the input program is used as is as the
registered program number.
2 When the 8–digit program number function is used, use
parameter No.3219 instead of parameter No.3218.
3219
Program number to be registered in synchronous input/output operation (8–digit
program number)
[Data type] 2–word
[Valid data range] 0 to 99999999
When a program entered through the input/output unit is executed and
registered in memory at the same time in synchronous input/output
operation, this parameter sets a program number for that program.
NOTE
1 If a value that falls outside the valid data range is specified,
the number of the input program is used as is as the
registered program number.
2 When the 8–digit program number function is not used, use
parameter No.3218 instead of parameter No.3219.