4. DESCRIPTION OF PARAMETERS
B–63010EN/02
176
#7
3455
#6 #5 #4 #3 #2 #1 #0
AXD
[Data type] Bit axis
AXD If a decimal point is omitted for an address with which a decimal point can
be used, the value is determined:
0 : In accordance with the least input increment.
1 : In millimeters, inches, or seconds. (calculator–type decimal point
input)
NOTE
1 This parameter is valid if bit 0 (DPI) of parameter No. 3401
is set to 0.
2 Because some addresses (such as R and K) are not related
to an axis, setting this parameter for all axes is not equivalent
to setting bit 0 (DPI) of parameter No. 3401 to 1.
3460
Address for second miscellaneous function
[Data type] Byte
This parameter specifies the address used for the second miscellaneous
function, as follows:
Address A B C U V W
Set value 65 66 67 85 86 87
Address B is assumed when a value other than the above is set.
Axes names cannot be used to specify the address.
Allowable difference between the specified end position and the end position obtained
from the increase/decrease and frequency in spiral interpolation or conic interpolation
3471
[Data type] 2–word axis
[Unit of data]
Increment system IS–A IS–B IS–C Units
Millimeter input 0.01 0.001 0.0001 mm
Inch input 0.001 0.0001 0.00001 inch
[Valid data range] 0 to 99999999
This parameter sets the maximum allowable difference (absolute value)
between the specified end position and the end position obtained from the
increase/decrease and frequency in spiral or conic interpolation.