B–63010EN/02
4. DESCRIPTION OF PARAMETERS
323
6141 Distance D1 for level 1 (metric input)
6142 Distance D2 for level 2 (metric input)
6143 Distance D3 for level 3 (metric input)
6144 Distance D4 for level 4 (metric input)
6145 Distance D5 for level 5 (metric input)
6146 Distance D6 for level 6 (metric input)
[Data type] 2–word
[Unit of data]
Increment system IS–A IS–B IS–C Units
Linear axis (inch input) 0.01 0.001 0.0001 mm
Rotation axis 0.01 0.001 0.0001 deg
[Valid data range] 0 to 99999999
These parameters set the positioning distances used when the function for
adjusting the rapid traverse rate, time constant, and loop gain to one of
seven levels according to the positioning distance is used. (The settings
are common to all axes.)
6151 Distance D1 to the first stage (for inch input)
6152 Distance D2 to the second stage (for inch input)
6153 Distance D3 to the third stage (for inch input)
6154 Distance D4 to the fourth stage (for inch input)
6155 Distance D5 to the fifth stage (for inch input)
6156 Distance D6 to the sixth stage (for inch input)
[Data type] 2–word
[Unit of data]
Increment system IS–A IS–B IS–C Units
Linear axis (inch input) 0.001 0.0001 0.00001 mm
Rotation axis 0.01 0.001 0.0001 deg
[Valid data range] 0 to 99999999
These parameters set positioning distances when the function for 7–stage
switching of the rapid traverse rate, time constant, and loop gain based on
positioning distance is used. (These parameters are common to all axes.)