B–63010EN/02
4. DESCRIPTION OF PARAMETERS
461
#7
HB88516
#6
HB7
#5
HB6
#4
HB5
#3
HB4
#2
HB3
#1
HB2
#0
HB1
#7
HBG8517
#6
HBF
#5
HBE
#4
HBD
#3
HBC
#2
HBB
#1
HBA
#0
HB9
[Data type] Bit
HB1 to HBG The signal is turned off when the corresponding high–speed position
switch passes through the machine coordinate position set in parameter
No. 8590 to 8599 or 12241 to 12246:
0 : In the negative (–) direction.
1 : In the positive (+) direction.
Bit name HB1 to HBG corresponds to the high–speed position switch
place.
When decision by direction is selected for the output type of a high–speed
position switch in parameter No. 8508 or 8509, the corresponding
parameter sets the direction.
8565 Output address of the high–speed position switch signal
NOTE
When this parameter has been set, the power must be
turned off before operation is contimued.
[Data type] Word
[Valid data range] 0, 1 to 127, 1000 to 1014, 1020 to 1034
This parameter sets the address of the Y signal which outputs the
high–speed position switch signal.
This parameter is valid when bit 0 (HPO) of parameter No. 8501 is set to 0.