B–63010EN/02
4. DESCRIPTION OF PARAMETERS
143
ISY When the
SYSTEM
function key is pressed while the system screen is being
displayed:
0 : The screen is changed.
1 : The screen is not changed.
IMS When the
MESSAGE
function key is pressed while the message screen is being
displayed:
0 : The screen is changed.
1 : The screen is not changed.
IUS When the
CUSTOM
or
GRAPH
function key is pressed while the custom or
graphic screen is being displayed:
0 : The screen is changed.
1 : The screen is not changed.
ICS When the
CUSTOM
function key is pressed while the custom screen is being
displayed:
0 : The screen is changed.
1 : The screen is not changed.
#7
3115
#6
D10x
#5 #4 #3
NDFx
NDFx
#2
SFMx
#1
NDAx
NDAx
#0
NDPx
NDPx
[Data type] Bit axis
NDPx Display of the current position for each axis
0 : The current position is displayed.
1 : The current position is not displayed.
NDAx Position display using absolute coordinates and relative coordinates is:
0 : Performed.
1 : Not performed. (Machine coordinates are displayed.)
SFMx In current position display, subscripts are:
0 : Added to the absolute, relative, and machine coordinate axis names.
1 : Assed only to the machine coordinate axis names.
NOTE
This parameter is disabled when two systems are controlled.
NDFx To the actual speed display, axis movement data is:
0 : Added.
1 : Not added.
NOTE
Even if the PCF parameter (bit 1 of parameter No.3105) is
set to 0, so as to add PMC controlled axis movement data
to the actual speed display, the movement data for a PMC
controlled axis for which NDFx is set to 1 is not added to the
actual speed display.