B–63010EN/02
4. DESCRIPTION OF PARAMETERS
135
[Data type] Bit
Select the language to be used for the display.
HUN DTH POR SPN HNG ITA CHI FRN GRM JPN Language
0 0 0 0 0 0 0 0 0 0 English
0 0 0 0 0 0 0 0 0 1 Japanese
0 0 0 0 0 0 0 0 1 0 German
0 0 0 0 0 0 0 1 0 0 French
0 0 0 0 0 0 1 0 0 0 Chinese
0 0 0 0 0 1 0 0 0 0 Italian
0 0 0 0 1 0 0 0 0 0 Korean
0 0 0 1 0 0 0 0 0 0 Spanish
0 0 1 0 0 0 0 0 0 0 Portuguese
0 1 0 0 0 0 0 0 0 0 Dutch
1 0 0 0 0 0 0 0 0 0 Hungarian
#7
ABR
3103
#6 #5 #4 #3 #2
NMH
NMH
#1
DIP
#0
[Data type] Bit
D1P When two–path control is applied, the current position display screen
displays:
0 : The current positions of the two paths regardless of the tool post select
signal.
1 : The current position of a path selected by the tool post select signal.
NOTE
Set this parameter when using the display with seven soft
keys.
NMH The system alarm history screen is:
0 : Not displayed.
1 : Displayed.
ABR When two systems are controlled using a 7–pieces type soft key display unit
and absolute position/relative position display requires two current position
display screens (when five or more controlled axes are involved in total):
0 : The first screen displays tool post 1 data and the second screen
dispiays tool post 2 data.
1 : The first screen displays the data of the tool post selected with the tool
post selection signal and the second screen displays the data of the
other tool post.
NOTE
When ABR=1, bit7 (SBA) of parameter No.3101 is disabled.