B–63010EN/02
4. DESCRIPTION OF PARAMETERS
145
#7
P9D3117
#6 #5 #4 #3 #2 #1
SPP
#0
P9D SPP SMS
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
SMS On the program check screen, the soft key to enable or disable the graph of
spindle speed and load is:
0 : Not displayed.
1 : Displayed.
SPP On the diagnostic screen, spindle position data (the number of pulses from
the position coder, detected after the detection of the one–revolution
signal) is:
0 : Not displayed.
1 : Displayed. (Diagnostic Nos. 445 to 447)
P9D The format of the screen displayed on the PC side by the NC screen
display function is:
0 : 14–inch type.
1 : 9–inch type.
This parameter is valid when the NC is not equipped with a display unit.
#7
3118
#6 #5 #4 #3
AS4
#2
AS3
#1
AS2
#0
AS1
[Data type] Bit
AS1 to AS4 When the actual spindle speeds (SACT) of the first spindle, second
spindle, third spindle, and fourth spindle are displayed, each value is:
0 : The value calculated based on the feedback pulses from the position
coder.
1 : The value calculated from the spindle motor speed (the same as the
spindle speed displayed on the operating monitor screen).
NOTE
The fourth serial spindle can be used only with the 16i.
#7
NVG
3119
#6 #5 #4
F2K
#3
TPA
TPA
#2
DDS
DDS
#1
POR
POR
#0
NVG
NOTE
When this parameter is set, the power must be turned off
before operation is continued.