B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 111 -
1844
Distance to the first grid point after the deceleration dog is turned off in the
case where the reference position shift amount of the reference position
shift function is 0
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] -999999999 to 999999999
Set a distance to the first grid point after the deceleration dog is turned
off in the case where the reference position shift amount (No. 1850) is
0.
NOTE
This parameter is automatically set if reference
position return is performed when bit 4 (SFDx) of
parameter No. 1008 is set to 1, the distance to the
first grid point after the deceleration dog is turned
off (parameter No. 1844) is set to 0, and the
reference position shift amount (parameter No.
1850) is set to 0.
Do not change an automatically set value.
1846 Distance for starting the second stage of smooth backlash compensation
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 999999999
For each axis, set the distance from the point where the axis
movement direction is reversed to the point where the second stage of
smooth backlash compensation is started.
1847 Distance for ending the second stage of smooth backlash compensation
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 999999999
For each axis, set the distance from the point where the axis
movement direction is reversed to the point where the second stage of
smooth backlash compensation is ended.