4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 262 -
5164
Percentage of the spindle speed to be changed at the start of the next
advancing after an overload torque detection signal is received
[Input type] Parameter input
[Data type] Word path
[Unit of data] %
[Valid data range] 1 to 255
This parameter sets the percentage of the spindle speed to be changed
at the start of the next advancing after the tool is retracted because the
overload torque detection signal is received.
S2 = S1 × d1 ÷ 100
S1: Spindle speed to be changed
S2: Spindle speed changed
Set d1 as a percentage.
NOTE
When 0 is set, the spindle speed is not changed.
5165
Percentage of the spindle speed to be changed at the start of the next
advancing when no overload torque detection signal is received
[Input type] Parameter input
[Data type] Word path
[Unit of data] %
[Valid data range] 1 to 255
This parameter sets the percentage of the spindle speed to be changed
at the start of the next advancing after the tool is retracted without the
overload torque detection signal received.
S2 = S1 × d2 ÷ 100
S1: Spindle speed to be changed
S2: Spindle speed changed
Set d2 as a percentage.
NOTE
When 0 is set, the spindle speed is not changed.