B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 329 -
4.34 PARAMETERS OF EXTERNAL DATA INPUT/OUTPUT
#7 #6 #5 #4 #3 #2 #1 #0
6300 EEX ESR ESC
[Input type] Parameter input
[Data type] Bit path
# 3 ESC When a reset is input between the input of the external data input read
signal ESTB and the execution of a search, the external program
number search function:
0: Performs a search.
1: Does not perform a search.
# 4 ESR The external program number search function is:
0: Disabled.
1: Enabled.
# 7 EEX PMC EXIN function
0: Conventional specifications
1: Extended specifications
If you want to use external machine coordinate system shift which
handles ±10.000 or more shift unavailable with the PMC/EXIN
command in the conventional specifications, set 1.
When this function is used for a multi-path system, the setting for path
1 is used.
For details of EXIN and how to change ladder software, refer to the
PMC manuals.
#7 #6 #5 #4 #3 #2 #1 #0
6301 EED NNO EXM EXA
[Input type] Parameter input
[Data type] Bit machine group
# 0 EXA This bit selects an external alarm message specification.
0: A message number from 0 to 999 can be sent. The CNC adds
1000 to an alarm number for distinction from general alarms.
1: A message number from 0 to 4095 can be sent. The CNC
prefixes the character string "EX" to a alarm number for display.
# 1 EXM This bit selects an external operator message specification.
0: A message number from 0 to 999 can be sent. The message of a
message number from 0 to 99 is displayed together with its
number. The CNC adds 2000 to a number for distinction. A
message number from 100 to 999 is not displayed on the screen,
but only the corresponding message is displayed on the screen.
1: A message number from 0 to 4095 can be sent. The message of a
message number from 0 to 99 is displayed together with its
number. The CNC prefixes the character string "EX" to a
message number for display. A message number from 100 to