B-63950EN/02 3.INPUTTING AND OUTPUTTING PARAMETERS THROUGH THE READER/PUNCHER INTERFACE
- 5 -
3.1 OUTPUTTING PARAMETERS THROUGH THE
READER/PUNCHER INTERFACE
1 Select the EDIT mode or set to Emergency stop.
2 To select the parameter screen, press the
SYSTEM
function key as
many times as required, or alternatively press the
SYSTEM
function
key once, then the PARAM section select soft key.
3 Press the [(OPRT)] soft key to display operation select soft keys,
then press the forward menu key located at the right-hand side of
the soft keys to display another set of operation select keys
including [PUNCH].
4 Pressing the [PUNCH] soft key changes the soft key display as
shown below:
5 Press the [EXEC] soft key to start parameter output. When
parameters are being output, "PNCH" blinks in the state display
field on the lower part of the screen.
6 When parameter output terminates, "PNCH" stops blinking.
Press the
RESET
key to interrupt parameter output.