4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 54 -
#7 #6 #5 #4 #3 #2 #1 #0
1203 EMS
[Input type] Parameter input
[Data type] Bit path
# 0 EMS The extended external machine zero point shift function is:
0: Disabled.
1: Enabled.
NOTE
1 To use the extended external machine zero
point shift function, the external machine zero
point shift function or the external data input
function is required.
2 When the extended external machine zero
point shift function is enabled, the conventional
external machine zero point shift function is
disabled.
#7 #6 #5 #4 #3 #2 #1 #0
1205 R2O R1O
[Input type] Parameter input
[Data type] Bit path
# 4 R1O The output of the signal for the reference position is:
0: Disabled.
1: Enabled.
# 5 R2O The output of the signal for the second reference position is:
0: Disabled.
1: Enabled.
1220 External workpiece zero point offset value in each axis
[Input type] Setting input
[Data type] Real axis
[Unit of data] mm, inch, degree (input unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
This is one of the parameters that give the position of the zero point of
workpiece coordinate system (G54 to G59). It gives an offset of the
workpiece zero point common to all workpiece coordinate systems. In
general, the offset varies depending on the workpiece coordinate
systems. The value can be set from the PMC using the external data
input function.