4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 268 -
0: The in-position widths dedicated to rigid tapping (parameters
Nos. 5300, 5302, 5304, and 5306) are selected.
1: The normal in-position width (parameter No. 1826) is selected.
#7 #6 #5 #4 #3 #2 #1 #0
5203 RBL OVS RFF HRM HRG
[Input type] Parameter input
[Data type] Bit path
# 0 HRG Rigid tapping by the manual handle is:
0: Disabled.
1: Enabled.
# 1 HRM When the tapping axis moves in the negative direction during rigid
tapping controlled by the manual handle, the direction in which the
spindle rotates is determined as follows:
0: In G84 mode, the spindle rotates in a normal direction. In G74
mode, the spindle rotates in reverse.
1: In G84 mode, the spindle rotates in reverse. In G74 mode, the
spindle rotates in a normal direction.
# 2 RFF In rigid tapping, feed forward is:
0: Disabled.
1: Enabled.
# 4 OVS In rigid tapping, override by the feedrate override select signal and
cancellation of override by the override cancel signal is:
0: Disabled.
1: Enabled.
When feedrate override is enabled, extraction override is disabled.
The spindle override is clamped to 100% during rigid tapping,
regardless of the setting of this parameter.
# 5 RBL As acceleration/deceleration for rigid tapping cutting feed:
0: Linear acceleration/deceleration is used.
1: Bell-shaped acceleration/deceleration is used.
5210 Rigid tapping mode specification M code
[Input type] Parameter input
[Data type] 2-word path
[Valid data range] 0 to 65535
This parameter sets an M code that specifies the rigid tapping mode.
The M code is judged to be 29 (M29) when "0" is set.