4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 190 -
# 1 SAT Check of the spindle speed arrival signal at the start of executing the
thread cutting block
0: The signal is checked only when SAR, #0 of parameter 3708, is
set.
1: The signal is always checked irrespective of whether SAR is set.
NOTE
When thread cutting blocks are consecutive, the
spindle speed arrival signal is not checked for the
second and subsequent thread cutting blocks.
# 5 SOC During constant surface speed control (G96 mode), the speed clamp
by the maximum spindle speed clamp command (M series: G92 S_; T
series: G50 S_;) is carried out:
0: Before spindle speed override.
1: After spindle speed override.
If this parameter is set to 0, the spindle speed may exceed the
maximum spindle speed (numeric value following S in G92 S_; (M
series) or G50 S_; (T series)).
If this parameter is set to 1, the spindle speed is limited to the
maximum spindle speed.
The spindle speed is limited to the upper limit of spindle speed
specified in parameter No. 3772, irrespective of the setting of this
parameter.
# 6 TSO During a threading or tapping cycle, the spindle override is:
0: Disabled (tied to 100%).
1: Enabled.
NOTE
During rigid tapping, the override is tied to 100%,
irrespective of the setting of this parameter.
#7 #6 #5 #4 #3 #2 #1 #0
3709 MRS MSI RSC SAM
[Input type] Parameter input
[Data type] Bit path
# 0 SAM The sampling frequency to obtain the average spindle speed
0: 4 (Normally, set to 0.)
1: 1
# 1 RSC In the constant surface speed control mode, the surface speed of a
rapid traverse block is calculated:
0: In accordance with the coordinates of the end point.
1: In accordance with the current value, as in cutting feed.
# 2 MSI In multi-spindle control, the SIND signal is valid
0: Only when the first spindle is valid (SIND signal for the 2nd, 3rd
spindle becomes ineffective) (TYPE-A)