B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 119 -
# 7 PM2 The second separate detector interface unit is:
0: Not used.
1: Used.
NOTE
When automatic setting mode is selected for FSSB
setting (when the parameter FMD (No.1902#0) is
set to 0), this parameter is automatically set when
input is performed with the FSSB setting screen.
When manual setting 2 mode is selected for FSSB
setting (when the parameter FMD (No.1902#0) is
set to 1), this parameter must be set directly. When
a separate detector interface unit is used, a
connector number must be set in the
corresponding parameter (No.1936, No.1937,
No.1938, or No.1939).
1936 Connector number of the first separate detector interface unit
1937 Connector number of the second separate detector interface unit
1938 Connector number of the third separate detector interface unit
1939 Connector number of the fourth separate detector interface unit
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte axis
[Valid data range] 0 to 7
Set the connector numbers corresponding to connectors to be
connected when the separate detector interface unit set by bit 1, 2, 6,
or 7 of parameter No. 1905 is used. The values to be set are
indicated below.
Within one separate detector interface unit, use connector numbers
sequentially. No intermediate number may be omitted.
Correspondence between connectors and connector numbers
Connector Connector number
JF101 0
JF102 1
JF103 2
JF104 3
JF105 4
JF106 5
JF107 6
JF108 7