B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 307 -
#7 #6 #5 #4 #3 #2 #1 #0
6010 *7 *6 *5 *4 *3 *2 *1 *0
#7 #6 #5 #4 #3 #2 #1 #0
6011 =7 =6 =5 =4 =3 =2 =1 =0
#7 #6 #5 #4 #3 #2 #1 #0
6012 #7 #6 #5 #4 #3 #2 #1 #0
#7 #6 #5 #4 #3 #2 #1 #0
6013 [7 [6 [5 [4 [3 [2 [1 [0
#7 #6 #5 #4 #3 #2 #1 #0
6014 ]7 ]6 ]5 ]4 ]3 ]2 ]1 ]0
#7 #6 #5 #4 #3 #2 #1 #0
6015 ?7 ?6 ?5 ?4 ?3 ?2 ?1 ?0
#7 #6 #5 #4 #3 #2 #1 #0
6016 @7 @6 @5 @4 @3 @2 @1 @0
#7 #6 #5 #4 #3 #2 #1 #0
6017 &7 &6 &5 &4 &3 &2 &1 &0
#7 #6 #5 #4 #3 #2 #1 #0
6018 _7 _6 _5 _4 _3 _2 _1 _0
[Input type] Parameter input
[Data type] Bit path
*0 to *7 : The bit pattern of the EIA or ISO/ASCII code indicating * is set.
=0 to =7 : The bit pattern of the EIA or ISO/ASCII code indicating = is set.
#0 to #7 : The bit pattern of the EIA or ISO/ASCII code indicating # is set.
[0 to [7 : The bit pattern of the EIA or ISO/ASCII code indicating [ is set.
]0 to ]7 : The bit pattern of the EIA or ISO/ASCII code indicating ] is set.
?0 to ?7 : The bit pattern of the EIA or ISO/ASCII code indicating ? is set.
@0 to @7 : The bit pattern of the EIA or ISO/ASCII code indicating @ is set.
&0 to &7 : The bit pattern of the EIA or ISO/ASCII code indicating & is set.
_0 to _7 : The bit pattern of the EIA or ISO/ASCII code indicating _ is set.
0: A corresponding bit is 0.
1: A corresponding bit is 1.
6030 M code to execute external device subprogram calls
[Input type] Setting input
[Data type] 2-word path
[Valid data range] 0 to 99999999
Set the M code to execute external device subprogram calls. When 0 is
set, M198 is used. M01, M02, M30, M98, and M99 cannot be used to
execute external device subprogram calls. When a negative number, 1,
2, 30, 98, or 99 is set for this parameter, M198 is used to execute
external device subprogram calls.