B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 499 -
4.71 PARAMETER OF LINEAR SCALE WITH ABSOLUTE
ADDRESS REFERENCE POSITION
14010
Maximum allowable travel distance when the reference position is
established for a linear scale with an absolute address reference position
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 99999999
This parameter sets the maximum allowable travel distance at the FL
feedrate when the reference position is established for a linear scale
with an absolute address reference position. When the travel
distance exceeds the setting of this parameter, the alarm (PS5326)
(SCALE WITH REFERENCE POSITION: REFERENCE
POSITION ESTABLISHMENT FAILED) is issued. When this
parameter is set to 0, the maximum allowable travel distance is not
checked.