B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 69 -
# 1 JOV Jog override is:
0: Enabled
1: Disabled (tied to 100%)
# 3 OV2 Signals used for 2nd feedrate override are
0: *AFV0 to AFV7 <G013> (specified every 1%)
1: *APF00 to *APF15 <G094, G095> (specified every 0.01%)
# 4 JRV Jog feed or incremental feed is
0: Performed at feed per minute.
1: Performed at feed per rotation.
NOTE
1 Specify a feedrate in parameter No.1423.
2 For the machining center system, the option for
threading/synchronous feed is required.
#7 #6 #5 #4 #3 #2 #1 #0
RTV HTG ROC
1403
HTG
[Input type] Parameter input
[Data type] Bit path
# 4 ROC In the threading cycles G92 and G76, rapid traverse override for
retraction after threading is finished is:
0: Effective
1: Not effective (Override of 100%)
# 5 HTG The feedrate for helical interpolation/helical involute
interpolation/three-dimensional circular interpolation is:
0: Specified using the feedrate along the tangent to an arc/involute
curve/three-dimensional arc
1: Specified using the feedrate along axes including a linear axis
(specified axes other than the circular interpolation axis in the
case of three-dimensional circular interpolation)
# 7 RTV Rapid traverse override while the tool is retracting in threading
0: Rapid traverse override is effective.
1: Rapid traverse override is not effective.