4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 432 -
8661 Variable area size
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word path
[Unit of data] KByte
[Valid data range] 0 to 59(251)
This parameter specifies the size of the static variable area that can be
shared by tasks. Specify a value in 1K-byte units. The maximum size
is 59K bytes (251K bytes if an optional 256KB SRAM is added). The
total of the SRAM disk size and the value of this parameter should not
exceed the available SRAM size minus 1K bytes (that is, 63K or 255K
bytes).
When the setting of this parameter is changed, the variable area and
SRAM disk are initialized.
8662 SRAM disk size
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word path
[Unit of data] KByte
[Valid data range] 4 to 63(255)
This parameter sets the size of the SRAM disk when the C language
executor is used. Specify a value greater than or equal to 4K bytes in
1K-byte units. The maximum size is 63K bytes (255K bytes if the
optional 256KB SRAM is added). The total of the variable area size
and the value of this parameter should not exceed the available SRAM
size minus 1K bytes (that is, 63K or 255K bytes).
8663 Time zone setting
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] 2-word path
[Unit of data] sec
[Valid data range] -12x3600 to 12x3600
This parameter specifies the time-zone difference from Greenwich
Mean Time in seconds. The difference for Japan is -9 hours. (The
setting is -9×3600 = 32400 seconds)
8760 Program number of data input/output (Power Mate CNC manager)