4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 342 -
7041 Retraction distance in tool retract and return
[Input type] Setting input
[Data type] Real axis
[Unit of data] mm, inch, deg (input unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
This parameter sets the retraction distance used when G10.6 is
specified alone for the tool retract and return function. The tool is
retracted by the distance set for this parameter in the incremental
mode. This data is valid only when bit 2 (RPS) of parameter No.
7040 is set to 1.
#7 #6 #5 #4 #3 #2 #1 #0
7055 BCG
[Input type] Parameter input
[Data type] Bit path
# 3 BCG The bell-shaped acceleration/deceleration time constant change
function is:
0: Disabled.
1: Enabled.
7066
Acceleration/deceleration reference speed for the bell-shaped
acceleration/deceleration time constant change function
[Input type] Setting input
[Data type] Real path
[Unit of data] mm/min, inch/min, degree/min (input unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
This parameter is used when the pre-interpolation bell-shaped
acceleration/deceleration time constant change function is used.