4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 78 -
1466 Feedrate for retraction in threading cycle G92 or G76
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm/min, inch/min (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
When threading cycle G92 or G76 is specified, retraction is performed
after threading. Set a feedrate for this retraction.
NOTE
When this parameter is set to 0 or bit 1 (CFR) of
parameter No. 1611 is set to 1, the rapid traverse
rate set in parameter No. 1420 is used.