B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 163 -
# 4 M30 When M30 is specified in a memory operation:
0: M30 is sent to the machine, and the head of the program is
automatically searched for. So, when the ready signal FIN is
returned and a reset or reset and rewind operation is not
performed, the program is executed, starting from the beginning.
1: M30 is sent to the machine, but the head of the program is not
searched for. (The head of the program is searched for by the
reset and rewind signal.)
# 5 M02 When M02 is specified in memory operation
0: M02 is sent to the machine, and the head of the program is
automatically searched for. So, when the end signal FIN is
returned and a reset or reset and rewind operation is not
performed, the program is executed, starting from the beginning.
1: M02 is sent to the machine, but the head of the program is not
searched for. (The head of the program is searched for by the
reset and rewind signal.)
# 7 M3B The number of M codes that can be specified in one block
0: One
1: Up to three