B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 513 -
#7 #6 #5 #4 #3 #2 #1 #0
19515 ZG2 BEX
[Input type] Parameter input
[Data type] Bit path
# 0 BEX When the tapping mode (G63) or a canned cycle is specified, the
mode for acceleration/deceleration before look-ahead interpolation is:
0: Turned off.
1: Not turned off.
# 1 ZG2 When the deceleration function based on cutting load in AI contour
control (deceleration based on Z-axis fall angle) is used:
0: Stepwise override values are applied.
1: Inclined override values are applied.
This parameter is valid only when bit 4 (ZAG) of parameter No. 8451
is set to 1.
When this parameter is set to 1, be sure to set parameter Nos. 19516,
8456, 8457, and 8458.
19516
Override for area 1 in deceleration based on cutting load in AI contour
control
[Input type] Parameter input
[Data type] Word path
[Unit of data] %
[Valid data range] 1 to 100
This parameter sets an override value for area 1 when the deceleration
function based on cutting load in AI contour control is used.
This parameter is valid only when bit 1 (ZG2) of parameter No. 19515
is set to 1.