B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 547 -
19751 Limit of the deviation from the path (for rapid traverse)
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm, inch (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
This parameter sets the limit of the deviation from the path in the rapid
traverse mode in tool tip point control for 5-axis machining.
If the tool moves at the specified rate, the deviation from the path may
exceed the value specified in this parameter. In this case, the rate is
decreased so that the tool moves along the path.
This parameter is valid when bit 6 (CRS) of parameter No. 19746 is
set to 1.
When 0 is set, the least input increment is assumed to be the limit of
the deviation from the path.
If a negative value is set, the rapid traverse rate is not decreased.
NOTE
The error generated after the rate is decreased
may be smaller than the value set in this parameter
depending on the calculation error.
19752 Limit of the deviation from the path (for cutting feed)
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm, inch (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
This parameter sets the limit of the deviation from the path in the
cutting feed mode in tool tip point control for 5-axis machining.
If the tool moves at the specified rate, the deviation from the path may
exceed the value specified in this parameter. In this case, the rate is
decreased so that the tool moves along the path.
This parameter is valid when bit 6 (CRS) of parameter No. 19746 is
set to 1.
When 0 is set, the least input increment is assumed to be the limit of
the deviation from the path.
If a negative value is set, the cutting feedrate is not decreased.
NOTE
The error generated after the rate is decreased
may be smaller than the value set in this parameter
depending on the calculation error.