4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 348 -
4.44 PARAMETERS OF SOFTWARE OPERATOR'S PANEL
#7 #6 #5 #4 #3 #2 #1 #0
7200 OP7 OP6 OP5 OP4 OP3 OP2 OP1
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 0 OP1 Mode selection on software operator's panel
0: Not performed
1: Performed
# 1 OP2 JOG feed axis select and manual rapid traverse select on software
operator's panel
0: Not performed
1: Performed
# 2 OP3 Manual pulse generator's axis select and manual pulse generator's
magnification select on software operator's panel
0: Not performed
1: Performed
# 3 OP4 JOG feedrate override select, feedrate override select, and rapid
traverse override select on software operator's panel
0: Not performed
1: Performed
# 4 OP5 Optional block skip select, single block select, machine lock select,
and dry run select on software operator's panel
0: Not performed
1: Performed
# 5 OP6 Protect key on software operator's panel
0: Not performed
1: Performed
# 6 OP7 Feed hold on software operator's panel
0: Not performed
1: Performed