B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 43 -
NOTE
RAA is valid when bit 0 (ROA) of parameter No. 1008
is set to 1 and bit 1 (RAB) of parameter No. 1008 is
set to 0.
To use this function, the option for rotary axis control
is required.
# 4 GRDx For the axis on which absolute values are detected, when
correspondence between the machine position and the position by the
absolute position detector is not completed, setting of the reference
position without dogs is:
0: Not performed two or more times.
1: Performed two or more times.
# 5 G90x A command for a rotary controlled axis is:
0: Regarded as an absolute/incremental command according to the
G90/G91 mode setting.
1: Regarded as an absolute command at all times.
#7 #6 #5 #4 #3 #2 #1 #0
1008 RMCx SFDx RRLx RABx ROAx
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 0 ROAx The roll-over function of a rotation axis is
0: Invalid
1: Valid
NOTE
ROAx specifies the function only for a rotation axis
(for which ROTx, #0 of parameter No.1006, is set to
1)
# 1 RABx In the absolute commands, the axis rotates in the direction
0: In which the distance to the target is shorter.
1: Specified by the sign of command value.
NOTE
RABx is valid only when ROAx is 1.
# 2 RRLx Relative coordinates are
0: Not rounded by the amount of the shift per one rotation
1: Rounded by the amount of the shift per one rotation