B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 61 -
1324
Coordinate value I of stored stroke check 3 in the positive direction on each axis
1325
Coordinate value I of stored stroke check 3 in the negative direction on each axis
[Input type] Setting input
[Data type] Real axis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Set the coordinate value of stored stroke check 3 on each axis in the +
or - direction in the machine coordinate system.
NOTE
1 Specify diameter values for any axes for which
diameter programming is specified.
2 The area inside the area set by parameter No.
1324 and No. 1325 is a prohibited area.
1326
Coordinate value II of stored stroke check 1 in the negative direction on each axis
1327
Coordinate value II of stored stroke check 1 in the negative direction on each axis
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Set the coordinate value of stored stroke check 1 on each axis in the +
or - direction in the machine coordinate system.
When the stored stroke check switch signal EXLM is set to 1, or the
stored stroke check switch signal for each axis direction +EXLx is set
to 1, parameter No. 1326 and No. 1327 are used for stroke check
instead of parameter No.1320 and No. 1321.
NOTE
1 Specify diameter values for any axes for which
diameter programming is specified.
2 The area outside the area set by parameter No.
1326 and No. 1327 is a prohibited area.
3 The EXLM signal is valid only when bit 2 (LMS) of
parameter No. 1300 is set to 1.
4 The +EXLx signal is valid only when bit 0 (DLM) of
parameter No. 1301 is set to 1.